Product Literature
New!ChemScan®
UV-4100
Process Analyzers


CAPABILITIES

Continuous, On-Line,
Automatic Monitoring of
One or Two Sample Lines

Up to Four Parameters

Multiple Detection Ranges

Multiple Data
Output Capabilities

Up to Eight Concentration
Set Point Alarms

Continual Self Diagnostics
with Alarm

FEATURES

Multiple Wavelength UV
Absorbance Detection System

Integrated Multiple Sample
Line Manifold

Automatic Zero and Clean

Internal Data Logs

Benign, Inexpensive
Reagents

No Specific Ion Electrodes
to Clean or Replace

Simple to Use
Operator Interface


Sample handling and conditioning
accessories are available for this
and other ChemScan® Analyzers.
PARAMETERS

Ammonia (dissolved)
Phosphate (Total Inorganic, Poly)
Chlorine (Free, Total)
Nitrate - Nitrite - % Transmittance

See other Models
for additional Parameters

<b><i>ChemScan<sup>®</sup></i></b> Analyzer
FOR ON-LINE
AND REAL-TIME
WATER AND
WASTEWATER
ANALYSIS
APPLICATIONS

Municipal Potable Water
- Chloramination

Municipal Wastewater
- Process (with filtration)
- Effluent (without filter)

Industrial Wastewater

BENEFITS

A ChemScan® On-Line Analyzer
can automatically provide
operators with timely process
chemistry measurements,
without the need for frequent
manual sampling or laboratory
analysis. These measurements
can be used to:

Assure Process
Conformance

Control Energy and
Chemical Costs

Improve Process
Performance


TECHNICAL SPECIFICATIONS
FUNCTIONS AND OUTPUTS
   Measurement Principle
   Number of Wavelengths
   Spectral Range
   Calibration Technique
   Number of Parameters
   Parameter Options
   Data Communications
   Data Log
   Auto Zeroing
   Auto Cleaning
   Analyzer Pump
   Sample Conditioning
   Number of Sample Lines

PERFORMANCE SPECIFICATIONS
   Reading Interval
   Response Time
   Range
   Accuracy

   Precision

   Zero Drift


SAMPLE PARAMETERS
   Sample Pressure

   Sample Flow
   Filtration Requirement
   Strainer Requirement
   Sample Temperature
   Sample Turbidity
   Sample Suspended Solids


MAINTENANCE
   Light Source Replacement
   Internal Battery Replacement
   Zero/Clean Solution Refill
   Reagent Refill

INSTRUMENT SPECIFICATIONS
   Size
   Weight
   Mounting
   Finish Coating
   Power
   Power Connection
   Power Condition
   Operator Interface
   Sample Cell Material
   Sample Connection
   Waste Connection


OPERATING ENVIRONMENT
   Enclosure Ratings

   Ambient Temperature
   Relative Humidity

High Resolution, Ultraviolet Absorbance
256
200 - 450 nm
Pattern Recognition of Spectral Data
4 max. (Opt)
Primary Or Secondary Absorbance(See Table 1 or 2)
4 - 2OmA (8 outputs max.), RS-232, other formats optional
1000 Values Time/Date Stamped, 24 Calibration Spectra
YES (Std)
YES (Std)
YES (Std), Zeroing and Cleaning and Internal Sample Flow Only
YES (Opt), Direct Injection
1 to 2 thru Internal Manifold


3 - 9999 minutes
Parameter Dependent (3 - 5 min. typ.)
Parameter/Site Dependent
Parameter/Site Dependent
Typ. 2% to 5% of Range
Parameter/Site Dependent
Typ. 2% of Range
Parameter Dependent
Minimized with Auto Zero


Pressurized Sample Lines must be regulated to 10 psi maximum,
   with max. lift 5 ft.and max. run 20 ft. to sample location or line connection
0.5 to 5 l/min.. (1.5 1 flush/sampling)
NONE (For Samples Meeting Turbidity and Solids Requirements)
   Optional ultrafilter available for high solids or turbidity.
Mesh Opening of 2.0 mm Max.
10 - 600C (Std)
0 - 60 NTU (Std)
0 - 150 mg/l (Max)


Every 5 years
Every 2 years
As Required (2-4 weeks typ.)
As Required (2-4 weeks typ.)


40 x 20 x 10 in.
130 lbs.
Wall (Std) or Stand (Opt)
Baked Enamel on Steel (Std) or Stainless Steel (Opt)
120/240 VAC ±10%, 50-60 Hz, 10 Amps max.
Hard Wired (Std) or Plug (Opt)
Dedicated Branch Circuit Free From: surges/dips > 10%, RF and
  Switching Noise
2 x 20 LCD and 4 x 4 Keypad
Polymer Body with Quartz Windows
¼" FNPT Fitting
¼" FNPT Fitting (Open Drain Required)


NEMA 4 (Main Enclosure)
NEMA 3R (Optrode Enclosure)
5° - 35°C (Std)
0 - 100% (Non-Condensing)


Table 1
UV-4100 Analysis Options (Wastewater)
OptionNO3NO2NH3PO4%T or AUSample LinesOutputs
1XXX.X14
2XXXX.14
3X.XXX14
4XXX.X28
5XXXX.28
6X.XXX28
7X.X..12
8X.X..24
9XXX..26


Table 2
UV-4100 Analysis Options (Potable Water)
OptionFree NH3Free CI2MonochloramineTotal CI2Sample LinesOutputs
10X..X12
11X.X.12
12X.XX13
13XXX.1 Plus 12 Plus 1
14XX..1 Plus 11 Plus 1
15X..X24
16X.X.24
17X.XX26


Notes:
  1. Technical Specifications are subject to change without prior notice.

ChemScan®
Product Installation
Drawing #4100

Download ASA-4100.pdf
     (Adobe Acrobat® format; 168 kbytes)
Don't have Acrobat®?
Get Acrobat Reader
http://www.adobe.com
Est. Download Time:
14.4 kbps - 112 seconds
28.8 kbps - 55 seconds
56 kbps - 28 seconds
Acrobat is © Adobe Corp.

Applications | Parameters | Product Selection | News
Why ChemScan | Technical Articles | Openings | Contact Us
Resources | F.A.Q. | Product Literature | Subscribe
Site Map | Search Our Site | Home Page

Applied Spectrometry Associates, Inc.
2325 Parklawn Drive, Suite I · Waukesha, WI 53186
Phone: 262-717-9500 · Fax: 262-717-9530
Toll Free: 800-665-7133
info@chemscan.com

Website production & hosting by onyourmark OnYourMark, LLC
Copyright © Applied Spectrometry Associates, Inc. All Rights Reserved | Privacy Statement