ChemScan® Application Summary

Dechlorination Control in Chloraminated Wastewater

Statement of the Problem

Chloramination of partially nitrified or un-nitrified wastewater is seldom carried far enough to produce free chlorine, because of the substantial demand from ammonia, amine and organic compounds present in the wastewater. Depending on relative concentrations of ammonia and organic nitrogen present and on the realtive feed rate of chlorine, reaction time, temperature and sample pH, monochloramine or other forms of combined chlorine may be formed.

Process Control Strategy

Dechlorinatin of chloraminated wastewater requires the detection of combined chlorine residuals. One strategy is to feed a dechlorinating agent such as sodium thosulfite, sulfur dioxide or other similar compound based on the desired effluent residual, which will be in the combined chlorine (chloramine) form.

Apparatus

ChemScan® Process Analyzers are designed to detect ammonia, chloramine or both in wastewater from one or more points in the treatment process.

Monochloramine is detected directly in wastewater at a standard pH of 6-9, without the need for reagents or pH buffer. Results may be reported as ppm or NH2Cl or as ppm of Cl. Trace concentrations (less tham 0.3 ppm of NH2Cl) may require an expanded path length flow cell for analysis down to concentrations of 0.05 of NH2Cl or less.

An alternate method of chloramine analysis injects a pH buffer to force monochloramine into the di- or tri-chloramine state, and compares the difference in absorbance spectra before and after the pH change.


Applications | Parameters | Product Selection | News
Why ChemScan | Technical Articles | Openings | Contact Us
Resources | F.A.Q. | Product Literature | Subscribe
Site Map | Search Our Site | Home Page

Applied Spectrometry Associates, Inc.
2325 Parklawn Drive, Suite I · Waukesha, WI 53186
Phone: 262-717-9500 · Fax: 262-717-9530
Toll Free: 800-665-7133
info@chemscan.com

Website production & hosting by onyourmark OnYourMark, LLC
Copyright © Applied Spectrometry Associates, Inc. All Rights Reserved | Privacy Statement